Cino FIXEDMOUNT FM400 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czytniki kodów kreskowych Cino FIXEDMOUNT FM400. Cino FIXEDMOUNT FM400 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 67
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
FIXED MOUNT SCANNER
Programming Manual
International Edition, Rev. A5
Przeglądanie stron 0
1 2 3 4 5 6 ... 66 67

Podsumowanie treści

Strona 1 - FIXED MOUNT SCANNER

FIXED MOUNT SCANNERProgramming ManualInternational Edition, Rev. A5

Strona 2

FuzzyScan Fixed Mount Scan Programming Manual 6 Under trigger mode, the scanner will turn on the light source to read barcode when it recei

Strona 3

FuzzyScan Fixed Mount Scan Programming Manual 7 Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar co

Strona 4

FuzzyScan Fixed Mount Scan Programming Manual 8 Programming ProceduresProgramming ProceduresProgramming ProceduresProgramming Procedures As you s

Strona 5

FuzzyScan Fixed Mount Scan Programming Manual 9 Scan “END” FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non

Strona 6

FuzzyScan Fixed Mount Scan Programming Manual 10 Single scan selectionSingle scan selectionSingle scan selectionSingle scan selection

Strona 7

FuzzyScan Fixed Mount Scan Programming Manual 11 Cycling scan selectionCycling scan selectionCycling scan selectionCycling scan selection

Strona 8

FuzzyScan Fixed Mount Scan Programming Manual 12 PROGRAM Host Interface Selection F_DEFAULT Family Code Selection P.C Parameter Selection Opti

Strona 9

FuzzyScan Fixed Mount Scan Programming Manual 13 PROGRAM Symbology Reading Control ♦♦♦♦ User Defined Symbol ID ♦♦♦♦ F_DEFAULT Family Code Sele

Strona 10 - Programming Manual

FuzzyScan Fixed Mount Scan Programming Manual 14 PROGRAM Symbology Reading Control ♦♦♦♦ Symbology ID Transmission ♦♦♦♦ F_DEFAULT Family Code S

Strona 11

FuzzyScan Fixed Mount Scan Programming Manual 15 PROGRAM Symbology Reading Control ♦♦♦♦ Readable Bar Code Setting ♦♦♦♦ F_DEFAULT Family Code S

Strona 12

FuzzyScan Fixed Mount Scan Programming Manual Revision History Rev. No. Released Date Description Rev. A May 26, 2010 First Release Rev. A1

Strona 13

FuzzyScan Fixed Mount Scan Programming Manual 16 PROGRAM Symbology Reading Control ♦♦♦♦ Code 39/Code 32 Setting ♦♦♦♦ F_DEFAULT Family Code Selec

Strona 14

FuzzyScan Fixed Mount Scan Programming Manual 17 PROGRAM Symbology Reading Control ♦♦♦♦ Code 39 Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.

Strona 15

FuzzyScan Fixed Mount Scan Programming Manual 18 PROGRAM Symbology Reading Control ♦♦♦♦ Codabar/NW-7 Setting ♦♦♦♦ F_DEFAULT Family Code Selectio

Strona 16

FuzzyScan Fixed Mount Scan Programming Manual 19 PROGRAM Symbology Reading Control ♦♦♦♦ UPC-A & UPC-E Setting ♦♦♦♦ F_DEFAULT Family Code S

Strona 17

FuzzyScan Fixed Mount Scan Programming Manual 20 PROGRAM Symbology Reading Control ♦♦♦♦ UPC-A & UPC-E Setting , Supplement Scan Voting♦♦♦♦ F

Strona 18

FuzzyScan Fixed Mount Scan Programming Manual 21 PROGRAM Symbology Reading Control ♦♦♦♦ EAN Setting , Supplement , Supplement Scan Voting♦♦♦♦ F_

Strona 19

FuzzyScan Fixed Mount Scan Programming Manual 22  UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN b

Strona 20

FuzzyScan Fixed Mount Scan Programming Manual 23 PROGRAM Symbology Reading Control ♦♦♦♦ UCC Coupon Extended Code Setting ♦♦♦♦ F_DEFAULT Family

Strona 21

FuzzyScan Fixed Mount Scan Programming Manual 24 PROGRAM Symbology Reading Control ♦♦♦♦ IATA & Interleaved 2 of 5 Setting ♦♦♦♦ F_DEFAULT F

Strona 22

FuzzyScan Fixed Mount Scan Programming Manual 25 PROGRAM Symbology Reading Control ♦♦♦♦ Code 25 Family Setting ♦♦♦♦ F_DEFAULT Family Code Sele

Strona 23

FuzzyScan Fixed Mount Scan Programming Manual © Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind wi

Strona 24

FuzzyScan Fixed Mount Scan Programming Manual 26 PROGRAM Symbology Reading Control ♦♦♦♦ Code 11 & Code 93 Setting ♦♦♦♦ F_DEFAULT Family Co

Strona 25

FuzzyScan Fixed Mount Scan Programming Manual 27 PROGRAM Symbology Reading Control ♦♦♦♦ MSI/Plessey Setting ♦♦♦♦ F_DEFAULT Family Code Selecti

Strona 26

FuzzyScan Fixed Mount Scan Programming Manual 28 PROGRAM Symbology Reading Control ♦♦♦♦ Code 128 & UCC/EAN 128 Setting ♦♦♦♦ F_DEFAULT Fami

Strona 27

FuzzyScan Fixed Mount Scan Programming Manual 29 PROGRAM Symbology Reading Control ♦♦♦♦ UK/Plessey Setting ♦♦♦♦ F_DEFAULT Family Code Selectio

Strona 28

FuzzyScan Fixed Mount Scan Programming Manual 30 PROGRAM Symbology Reading Control ♦♦♦♦ Telepen Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 29

FuzzyScan Fixed Mount Scan Programming Manual 31 PROGRAM Symbology Reading Control ♦♦♦♦ GS1 DataBar Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 30

FuzzyScan Fixed Mount Scan Programming Manual 32 PROGRAM Symbology Reading Control ♦♦♦♦ Linear-stacked & Korea Post Code Setting ♦♦♦♦ F_DEFA

Strona 31

FuzzyScan Fixed Mount Scan Programming Manual 33 PROGRAM Keyboard Interface Control ♦♦♦♦ Keyboard Layout (Language) Setting ♦♦♦♦ F_DEFAULT Famil

Strona 32

FuzzyScan Fixed Mount Scan Programming Manual 34 PROGRAM Keyboard Interface Control ♦♦♦♦ Record Suffix, Preamble, Postamble & Caps Lock ♦♦♦♦

Strona 33

FuzzyScan Fixed Mount Scan Programming Manual 35 PROGRAM Keyboard Interface Control ♦♦♦♦ Delay Setting ♦♦♦♦ F_DEFAULT Family Code Selection P

Strona 34

FuzzyScan Fixed Mount Scan Programming Manual Table of Contents Getting Started Getting Familiar with Your FuzzyScan 1 Connect to Your Host 2 Ins

Strona 35

FuzzyScan Fixed Mount Scan Programming Manual 36 PROGRAM Keyboard Interface Control ♦♦♦♦ Emulation Setting & Upper/Lower Case Setting ♦♦♦♦ F

Strona 36

FuzzyScan Fixed Mount Scan Programming Manual 37 PROGRAM Serial Interface Control ♦♦♦♦ Record Suffix, Preamble, Postamble Setting ♦♦♦♦ F_DEFAULT

Strona 37

FuzzyScan Fixed Mount Scan Programming Manual 38 PROGRAM Serial Interface Control ♦♦♦♦ Delay Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.C

Strona 38

FuzzyScan Fixed Mount Scan Programming Manual 39 PROGRAM Serial Interface Control ♦♦♦♦ Protocol, ACK/NAK Setting ♦♦♦♦ F_DEFAULT Family Code Se

Strona 39

FuzzyScan Fixed Mount Scan Programming Manual 40 PROGRAM Serial Interface Control ♦♦♦♦Time Out Setting, Baud Rate, Data Frame♦♦♦♦ F_DEFAULT Fa

Strona 40

FuzzyScan Fixed Mount Scan Programming Manual 41 PROGRAM Operation Control ♦♦♦♦ Operation Mode Setting ♦♦♦♦ F_DEFAULT Family Code Selection P

Strona 41

FuzzyScan Fixed Mount Scan Programming Manual 42 PROGRAM Operation Control ♦♦♦♦ Buzzer, Indicator, Inverse Reading♦♦♦♦ F_DEFAULT Family Code S

Strona 42

FuzzyScan Fixed Mount Scan Programming Manual 43 PROGRAM Operation Control ♦♦♦♦Dollar Sign, Redundancy, Scan Rate Control ♦♦♦♦ F_DEFAULT Family

Strona 43

FuzzyScan Fixed Mount Scan Programming Manual 44 PROGRAM Operation Control ♦♦♦♦ Delay Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.C Para

Strona 44

FuzzyScan Fixed Mount Scan Programming Manual 45 PROGRAM Operation Control ♦♦♦♦ Time-out and Duration Setting ♦♦♦♦ F_DEFAULT Family Code Selec

Strona 45

FuzzyScan Fixed Mount Scan Programming Manual 1 Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan FM400 Series Fixed Mount S

Strona 46

FuzzyScan Fixed Mount Scan Programming Manual 46 PROGRAM Operation Control ♦♦♦♦ Presentation Scanning Setting ♦♦♦♦ F_DEFAULT Family Code Selec

Strona 47

FuzzyScan Fixed Mount Scan Programming Manual 47 PROGRAM Operation Control ♦♦♦♦ OK/NG Signal and Beeping Control ♦♦♦♦ F_DEFAULT Family Code Se

Strona 48

FuzzyScan Fixed Mount Scan Programming Manual 48  The OK/NG Signal Active State can control the logic level in digit circuits design, you can adjust

Strona 49

FuzzyScan Fixed Mount Scan Programming Manual 49 PROGRAM Condensed DataWizard ♦♦♦♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦♦♦♦

Strona 50

FuzzyScan Fixed Mount Scan Programming Manual 50 PROGRAM Condensed DataWizard ♦♦♦♦ Data Formatter Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 51

FuzzyScan Fixed Mount Scan Programming Manual 51 PROGRAM Condensed DataWizard ♦♦♦♦ Data Verifier Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 52

FuzzyScan Fixed Mount Scan Programming Manual 52 PROGRAM Condensed DataWizard ♦♦♦♦ Data Replacer Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 53

FuzzyScan Fixed Mount Scan Programming Manual 53 PROGRAM Condensed DataWizard ♦♦♦♦ Data Organizer Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 54

FuzzyScan Fixed Mount Scan Programming Manual 54 Select a Bar Code SymbologySelect a Bar Code SymbologySelect a Bar Code SymbologySelect a Bar Co

Strona 55

FuzzyScan Fixed Mount Scan Programming Manual 55 Programming ProcedureProgramming ProcedureProgramming ProcedureProgramming Procedure [Data Verifi

Strona 56

FuzzyScan Fixed Mount Scan Programming Manual 2 Connect to Your Host Both RS232 and USB interfaces are available in different models of FM

Strona 57

FuzzyScan Fixed Mount Scan Programming Manual 56 Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag

Strona 58

FuzzyScan Fixed Mount Scan Programming Manual 57 Keyboard Function Code Table No. ANSI ASCII Key Function No. ANSI ASCII Key Function 00 NUL 0

Strona 59

FuzzyScan Fixed Mount Scan Programming Manual 58 ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu,

Strona 60

FuzzyScan Fixed Mount Scan Programming Manual 59 Host Interface Quick Set RS232 Serial USB Com Port Emulation USB HID Standard Mode USB

Strona 61

FuzzyScan Fixed Mount Scan Programming Manual 60 Option Codes 0 8 4 C 1 9 5 D 2 A 6 E 3 B 7 F FIN (Finish) END (Exi

Strona 62

FuzzyScan Fixed Mount Scan Programming Manual 61 System Commands PROGRAM (Enter Programming Mode) System Information List (SYSLIST) Save User

Strona 63

FuzzyScan Fixed Mount Scan Programming Manual 62 Indications Normal Operation Indicators Descriptions Power Status OK/NG Beeper Power on Ste

Strona 64

Fixed Mount Scanner Programming ManualCINO GROUPPC WORTH INT’L CO., LTD.www.cino.com.tw

Strona 65

FuzzyScan Fixed Mount Scan Programming Manual 3 Install Your FuzzyScan Adjust Reading Angle The readability may be impacted by the specular reflecti

Strona 66

FuzzyScan Fixed Mount Scan Programming Manual 4 Use the Test Mode The FuzzyScan FM400 provides an useful test mode which is helpful for you to quickl

Strona 67 - PC WORTH INT’L CO., LTD

FuzzyScan Fixed Mount Scan Programming Manual 5 Use Your FuzzScan Both FuzzyScan Barcode commands and Serial commands are available to co

Komentarze do niniejszej Instrukcji

Brak uwag