12
Operation Control
Command Parameter Selection Option Code
Inverse Reading
Disable
Enable
0
1
Redundancy
None
Level 1
Level 2
Level 3
Level 4
Level 5
Scan Voting
0
1
2
3
4
5
Power On Indicator
Disable (LED off)
LED steady on
LED flash
0
1
2
Buzzer Tone Control
Buzzer tone – mute
Buzzer tone – low
Buzzer tone – medium
Buzzer tone – high
Buzzer tone – extremely high
Power–on beep
No Power–on beep
0
1
2
3
4
5
6
Good Read Duration
Short
Medium
Long
Extremely long
Extremely short
0
1
2
3
4
Presentation Sensitivity
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
0
1
2
3
4
5
6
Hands Free Time-out
Short
Medium
Long
Extremely long
Disable
0
1
2
3
4
Scan Input Time-out
100 msec.
200 msec.
300 msec.
400 msec.
500 msec.
600 msec.
700 msec.
800 msec.
900 msec.
User define: 1-99 sec.
0
1
2
3
4
5
6
7
8
9, (2 digits)