Programming Procedure
Data Verifier
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to “08”
(Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to “16”.
Scan “1
st
Identified Character” and set the Identified position to “00”,
then set the identified character to “39” (Hex Code of 9).
Data Formatter
Scan “Formatter Control” and set bar code symbology to “08”.
Scan “1
st
Insertion” and set the identified position to “06”, then
inserted characters to “09” (Hex Code of TAB), “53” (Hex Code of S),
“4E” (Hex Code of N).
Scan “2
nd
Insertion” and set the identified position to “12”, then
inserted character to “09”. In the final, you must scan “FIN” (Finish)
code to terminate this selection.
Scan “3
rd
Insertion” and set the identified position to “16”, then
inserted character to “09”. In the final, you must scan “FIN” (Finish)
code to terminate the selection.
Data Changer
Scan “Changer Control” and set bar code symboloby to “08”.
Scan “1
st
substitute” and set the identified position to “00”, then
replaced character to “41” (Hex code of A).
Data Organizer
Scan “Organizer Control” and set bar code symboloby to “08”.
Scan “1
st
Organization” and set the identified position to “16”, then
set the data transmission to “0” (forward).
Scan “2
nd
Organization” and set the identified position to “17”, then
set the data transmission to “1” (backward).
Scan “END” (Exit) to terminate the programming.
Important Notice
Please note that Condensed DataWizard will follow the preset working
flow as below :
Verifier Formatter Changer Organizer
So when you set the identified position in Data Organizer, you must
consider the inserted data which you already set via Data Formatter.
MBC6890 User’s Guide