Cino SM5700 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Drukarki Cino SM5700. Cino SM5700 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 92
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Programming Manual
International Edition, Rev. A2
OEM SCAN MODULE
Przeglądanie stron 0
1 2 3 4 5 6 ... 91 92

Podsumowanie treści

Strona 1 - OEM SCAN MODULE

Programming ManualInternational Edition, Rev. A2OEM SCAN MODULE

Strona 2

FuzzyScan OEM Scan Module Programming Manual 5 Intelli Button For normal operation, the Intelli Button of the scan module acts as a manual Trigger Sw

Strona 3

FuzzyScan OEM Scan Module Programming Manual 6 Use Your FuzzyScan Both FuzzyScan Barcode commands and Serial commands are available to configure your

Strona 4

FuzzyScan OEM Scan Module Programming Manual 7 Operation Mode area-imaging scan module The details of each operation mode supported by SM5700 are

Strona 5

FuzzyScan OEM Scan Module Programming Manual 8 Operation Mode linear imaging scan module The details of each operation mode supported by SM380 sc

Strona 6

FuzzyScan OEM Scan Module Programming Manual 9 Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar cod

Strona 7

FuzzyScan OEM Scan Module Programming Manual 10 Programming ProceduresProgramming ProceduresProgramming ProceduresProgramming Procedures As you s

Strona 8

FuzzyScan OEM Scan Module Programming Manual 11 Scan “END” FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non

Strona 9

FuzzyScan OEM Scan Module Programming Manual 12 Single scan selectionSingle scan selectionSingle scan selectionSingle scan selection

Strona 10 - Programming Manual

FuzzyScan OEM Scan Module Programming Manual 13 Cycling scan selectionCycling scan selectionCycling scan selectionCycling scan selection

Strona 11

FuzzyScan OEM Scan Module Programming Manual 14 PROGRAM Host Interface Selection F_DEFAULT Family Code Selection P.C Parameter Selection Optio

Strona 12

FuzzyScan OEM Scan Module Programming Manual Revision History Rev. No. Released Date Description Rev. A1 May 2, 2014 First Release Rev. A2

Strona 13

FuzzyScan OEM Scan Module Programming Manual 15 PROGRAM Symbology Reading Control ♦♦♦♦ User Defined Symbol ID ♦♦♦♦ F_DEFAULT Family Code Selec

Strona 14

FuzzyScan OEM Scan Module Programming Manual 16 PROGRAM Symbology Reading Control ♦♦♦♦ User Defined Symbol ID ♦♦♦♦ F_DEFAULT Family Code Selec

Strona 15

FuzzyScan OEM Scan Module Programming Manual 17 PROGRAM Symbology Reading Control ♦♦♦♦ Symbology ID Transmission ♦♦♦♦ F_DEFAULT Family Code Se

Strona 16

FuzzyScan OEM Scan Module Programming Manual 18 PROGRAM Symbology Reading Control ♦♦♦♦ Readable Bar Code Setting ♦♦♦♦ F_DEFAULT Family Code Se

Strona 17

FuzzyScan OEM Scan Module Programming Manual 19 PROGRAM Symbology Reading Control ♦♦♦♦ Readable Bar Code Setting ♦♦♦♦ F_DEFAULT Family Code Se

Strona 18

FuzzyScan OEM Scan Module Programming Manual 20 PROGRAM Symbology Reading Control ♦♦♦♦ Code 39/Code 32 Setting ♦♦♦♦ F_DEFAULT Family Code Select

Strona 19

FuzzyScan OEM Scan Module Programming Manual 21 PROGRAM Symbology Reading Control ♦♦♦♦ Code 39 Setting♦♦♦♦ F_DEFAULT Family Code Selection P.C

Strona 20

FuzzyScan OEM Scan Module Programming Manual 22 PROGRAM Symbology Reading Control ♦♦♦♦ Codabar/NW-7 Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 21

FuzzyScan OEM Scan Module Programming Manual 23 PROGRAM Symbology Reading Control ♦♦♦♦ Codabar/NW-7 Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 22

FuzzyScan OEM Scan Module Programming Manual 24 PROGRAM Symbology Reading Control ♦♦♦♦ UPC-A & UPC-E Setting ♦♦♦♦ F_DEFAULT Family Code Se

Strona 23

FuzzyScan OEM Scan Module Programming Manual © Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with

Strona 24

FuzzyScan OEM Scan Module Programming Manual 25 PROGRAM Symbology Reading Control ♦♦♦♦ UPC-A & UPC-E Setting , Supplement Scan Voting♦♦♦♦ F_

Strona 25

FuzzyScan OEM Scan Module Programming Manual 26 PROGRAM Symbology Reading Control ♦♦♦♦ EAN Setting , Supplement , Supplement Scan Voting♦♦♦♦ F_D

Strona 26

FuzzyScan OEM Scan Module Programming Manual 27  UPC/EAN Security Level The scan module offers three levels of decode security for UPC/EA

Strona 27

FuzzyScan OEM Scan Module Programming Manual 28 PROGRAM Symbology Reading Control ♦♦♦♦ UCC Coupon Extended Code Setting ♦♦♦♦ F_DEFAULT Family

Strona 28

FuzzyScan OEM Scan Module Programming Manual 29 PROGRAM Symbology Reading Control ♦♦♦♦ IATA & Interleaved 2 of 5 Setting ♦♦♦♦ F_DEFAULT Fa

Strona 29

FuzzyScan OEM Scan Module Programming Manual 30 PROGRAM Symbology Reading Control ♦♦♦♦ Code 25 Family Setting ♦♦♦♦ F_DEFAULT Family Code Selec

Strona 30

FuzzyScan OEM Scan Module Programming Manual 31 PROGRAM Symbology Reading Control ♦♦♦♦ Code 11 & Code 93 Setting ♦♦♦♦ F_DEFAULT Family Cod

Strona 31

FuzzyScan OEM Scan Module Programming Manual 32 PROGRAM Symbology Reading Control ♦♦♦♦ MSI/Plessey Setting ♦♦♦♦ F_DEFAULT Family Code Selectio

Strona 32

FuzzyScan OEM Scan Module Programming Manual 33 PROGRAM Symbology Reading Control ♦♦♦♦ Code 128 Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 33

FuzzyScan OEM Scan Module Programming Manual 34 PROGRAM Symbology Reading Control ♦♦♦♦ GS1-128 Setting ♦♦♦♦ F_DEFAULT Family Code Selectio

Strona 34

FuzzyScan OEM Scan Module Programming Manual Regulatory LED Eye Safety IEC62471 Exempt group

Strona 35

FuzzyScan OEM Scan Module Programming Manual 35 PROGRAM Symbology Reading Control ♦♦♦♦ UK/Plessey Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 36

FuzzyScan OEM Scan Module Programming Manual 36 PROGRAM Symbology Reading Control ♦♦♦♦ Telepen Setting ♦♦♦♦ F_DEFAULT Family Code Selection P

Strona 37

FuzzyScan OEM Scan Module Programming Manual 37 PROGRAM Symbology Reading Control ♦♦♦♦ GS1 DataBar Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 38

FuzzyScan OEM Scan Module Programming Manual 38 PROGRAM Symbology Reading Control ♦♦♦♦ Composite Codes, PDF417/microPDF417, Codablock F Setting ♦♦♦♦

Strona 39

FuzzyScan OEM Scan Module Programming Manual 39 PROGRAM Symbology Reading Control ♦♦♦♦ Code 16K & Code 49 Setting ♦♦♦♦ F_DEFAULT Family Cod

Strona 40

FuzzyScan OEM Scan Module Programming Manual 40 PROGRAM Symbology Reading Control ♦♦♦♦ QR Code Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.

Strona 41

FuzzyScan OEM Scan Module Programming Manual 41 PROGRAM Symbology Reading Control ♦♦♦♦ Data Matrix Setting ♦♦♦♦ F_DEFAULT 11Family Code Selecti

Strona 42

FuzzyScan OEM Scan Module Programming Manual 42 PROGRAM Symbology Reading Control ♦♦♦♦MaxiCode Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.

Strona 43

FuzzyScan OEM Scan Module Programming Manual 43 PROGRAM Symbology Reading Control ♦♦♦♦ Aztec Code Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 44

FuzzyScan OEM Scan Module Programming Manual 44 PROGRAM Symbology Reading Control ♦♦♦♦ Australian Post, US Planet, US Postnet, British Post & Ja

Strona 45

FuzzyScan OEM Scan Module Programming Manual Table of Contents Getting Started Getting Familiar with Your FuzzyScan 1 Connect to Your Host 3 Conn

Strona 46

FuzzyScan OEM Scan Module Programming Manual 45 PROGRAM Symbology Reading Control ♦♦♦♦ Netherlands KIX Code, Intelligent Mail & Korea Post Code

Strona 47

FuzzyScan OEM Scan Module Programming Manual 46 PROGRAM Keyboard Interface Control ♦♦♦♦ Keyboard Layout (Language) Setting ♦♦♦♦ F_DEFAULT Family

Strona 48

FuzzyScan OEM Scan Module Programming Manual 47 PROGRAM Keyboard Interface Control ♦♦♦♦ Record Suffix, Preamble, Postamble FNC1 Transmit & Cap

Strona 49

FuzzyScan OEM Scan Module Programming Manual 48  FNC1 Symbol Char. Transmit: When this function is enabled and the FNC1 is contained in scanned data

Strona 50

FuzzyScan OEM Scan Module Programming Manual 49 PROGRAM Keyboard Interface Control ♦♦♦♦ Delay Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.

Strona 51

FuzzyScan OEM Scan Module Programming Manual 50 PROGRAM Keyboard Interface Control ♦♦♦♦ Emulation Setting & Upper/Lower Case Setting ♦♦♦♦ F_

Strona 52

FuzzyScan OEM Scan Module Programming Manual 51 PROGRAM Serial Interface Control ♦♦♦♦ Record Suffix, Preamble, Postamble Setting ♦♦♦♦ F_DEFAULT

Strona 53

FuzzyScan OEM Scan Module Programming Manual 52 PROGRAM Serial Interface Control ♦♦♦♦ Delay Setting ♦♦♦♦ F_DEFAULT Family Code Selection P.C

Strona 54

FuzzyScan OEM Scan Module Programming Manual 53 PROGRAM Serial Interface Control ♦♦♦♦ Protocol, ACK/NAK Setting ♦♦♦♦ F_DEFAULT Family Code Sel

Strona 55

FuzzyScan OEM Scan Module Programming Manual 54 PROGRAM Serial Interface Control ♦♦♦♦Time Out Setting, Baud Rate, Data Frame♦♦♦♦ F_DEFAULT Fam

Strona 56

FuzzyScan OEM Scan Module Programming Manual 1 Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Scan Module SM380/SM5700 Se

Strona 57

FuzzyScan OEM Scan Module Programming Manual 55 PROGRAM Operation Control SM380 ♦♦♦♦ Operation Mode Setting ♦♦♦♦ F_DEFAULT Family Code Selecti

Strona 58

FuzzyScan OEM Scan Module Programming Manual 56 PROGRAM Operation Control SM380 ♦♦♦♦1D Barcode Reading Direction, 1D Barcode Direction Indication Tr

Strona 59

FuzzyScan OEM Scan Module Programming Manual 57 PROGRAM Operation Control SM5700 ♦♦♦♦ Operation Control, Presentation Background lighting Control♦♦♦

Strona 60

FuzzyScan OEM Scan Module Programming Manual 58 PROGRAM Operation Control SM5700 ♦♦♦♦ Aiming Control, Delay Aiming, Illumination Control, Center

Strona 61

FuzzyScan OEM Scan Module Programming Manual 59 PROGRAM Operation Control SM5700 ♦♦♦♦ Batch Reading ♦♦♦♦ Unique Bar Code Reporting, Batch Rea

Strona 62

FuzzyScan OEM Scan Module Programming Manual 60  [Code length] Length: 4 byte Specify what length of data output will be acceptable for this symb

Strona 63

FuzzyScan OEM Scan Module Programming Manual 61 You would set up the Batch Reading rule with the following command line: [PROGRAM] [Batch Reading] [

Strona 64

FuzzyScan OEM Scan Module Programming Manual 62 The breakdown of the command line is shown below: 03 The number of elements in the overall rule 01

Strona 65

FuzzyScan OEM Scan Module Programming Manual 63 PROGRAM Operation Control SM380, SM5700 ♦♦♦♦ Buzzer, Indicator, 1D Barcode Inverse Reading♦♦♦♦ F

Strona 66

FuzzyScan OEM Scan Module Programming Manual 64 PROGRAM Operation Control SM380, SM5700 ♦♦♦♦Dollar Sign, Redundancy♦♦♦♦ F_DEFAULT Family Code Se

Strona 67

FuzzyScan OEM Scan Module Programming Manual 2 SM5700 OK/NG Indicator Status Indicator Power Indicator Main Processor Condenser Lens Tri

Strona 68

FuzzyScan OEM Scan Module Programming Manual 65 PROGRAM Operation Control SM380, SM5700 ♦♦♦♦ Reread Delay & Good Read Delay Setting ♦♦♦♦

Strona 69

FuzzyScan OEM Scan Module Programming Manual 66 PROGRAM Operation Control SM380, SM5700 ♦♦♦♦ Time-out and Duration Setting ♦♦♦♦ F_DEFAULT Fami

Strona 70

FuzzyScan OEM Scan Module Programming Manual 67 PROGRAM Operation Control SM380, SM5700 ♦♦♦♦ Presentation Sensitivity♦♦♦♦ F_DEFAULT Family Cod

Strona 71

FuzzyScan OEM Scan Module Programming Manual 68 PROGRAM Operation Control SM380, SM5700 OK/NG Signal and Beeping Control ♦♦♦♦ F_DEFAULT Fam

Strona 72

FuzzyScan OEM Scan Module Programming Manual 69  The OK/NG Signal Active State can control the logic level in digit circuits design, you can adjust

Strona 73

FuzzyScan OEM Scan Module Programming Manual 70 PROGRAM Condensed DataWizard ♦♦♦♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦♦♦♦ F

Strona 74

FuzzyScan OEM Scan Module Programming Manual 71 PROGRAM Condensed DataWizard ♦♦♦♦ Data Formatter Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 75

FuzzyScan OEM Scan Module Programming Manual 72 PROGRAM Condensed DataWizard ♦♦♦♦ Data Verifier Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 76

FuzzyScan OEM Scan Module Programming Manual 73 PROGRAM Condensed DataWizard ♦♦♦♦ Data Replacer Setting ♦♦♦♦ F_DEFAULT Family Code Selection

Strona 77

FuzzyScan OEM Scan Module Programming Manual 74 PROGRAM Condensed DataWizard ♦♦♦♦ Data Organizer Setting ♦♦♦♦ F_DEFAULT Family Code Selection P

Strona 78

FuzzyScan OEM Scan Module Programming Manual 3 Connect to Your Host FuzzyScan Scan Module is designed to support RS232 Serial, USB HID and USB

Strona 79

FuzzyScan OEM Scan Module Programming Manual 75 Select a Bar Code SymbologySelect a Bar Code SymbologySelect a Bar Code SymbologySelect a Bar Code Sy

Strona 80

FuzzyScan OEM Scan Module Programming Manual 76 Application ExampleApplication ExampleApplication ExampleApplication Example If your

Strona 81

FuzzyScan OEM Scan Module Programming Manual 77 [Data Replacer]  Scan “Replacer Control” and set bar code symbology to “48”.  Scan “1st Re

Strona 82

FuzzyScan OEM Scan Module Programming Manual 78 Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag C

Strona 83

FuzzyScan OEM Scan Module Programming Manual 79 2D Symbology ID Table Cino ID AIM ID Cino ID AIM ID Code Family Primary Format Hex Value Char. Cod

Strona 84

FuzzyScan OEM Scan Module Programming Manual 80 Keyboard Function Code Table No. ANSI ASCII Key Function Ctrl Output No. ANSI ASCII Key Functio

Strona 85

FuzzyScan OEM Scan Module Programming Manual 81 ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu,

Strona 86

FuzzyScan OEM Scan Module Programming Manual 82 Host Interface Quick Set RS232 Serial USB Com Port Emulation USB HID Standard Mode USB HID

Strona 87

FuzzyScan OEM Scan Module Programming Manual 83 Operation Mode Quick Set SM5700 Trigger Mode Force Mode (Continued power on) Alternati

Strona 88

FuzzyScan OEM Scan Module Programming Manual 84 Option Codes 0 A 5 F 1 B 6 2 C 7 3 D 8 4 E 9 FIN (Finish) Abor

Strona 89

FuzzyScan OEM Scan Module Programming Manual 4 Connecting Host Interface Standard RS232 Universal USB

Strona 90

FuzzyScan OEM Scan Module Programming Manual 85 System Commands PROGRAM (Enter Programming Mode) System Information List (SYSLIST) Save User

Strona 91

FuzzyScan OEM Scan Module Programming Manual 86 Power Indicator Status Indicator OK/NG Indicator Status Indications SM380 SM5700 Beeper and L

Strona 92 - PC WORTH INT’L CO., LTD

Scan Module Programming ManualCINO GROUPPC WORTH INT’L CO., LTD.www.cino.com.tw

Powiązane modele: SM380

Komentarze do niniejszej Instrukcji

Brak uwag